5,542 research outputs found

    Band Gap Closing in a Synthetic Hall Tube of Neutral Fermions

    Get PDF
    We report the experimental realization of a synthetic three-leg Hall tube with ultracold fermionic atoms in a one-dimensional optical lattice. The legs of the synthetic tube are composed of three hyperfine spin states of the atoms, and the cyclic inter-leg links are generated by two-photon Raman transitions between the spin states, resulting in a uniform gauge flux ϕ\phi penetrating each side plaquette of the tube. Using quench dynamics, we investigate the band structure of the Hall tube system for a commensurate flux ϕ=2π/3\phi=2\pi/3. Momentum-resolved analysis of the quench dynamics reveals that a critical point of band gap closing as one of the inter-leg coupling strengths is varied, which is consistent with a topological phase transition predicted for the Hall tube system.Comment: 8 pages, 8 figure

    Double resonance of Raman transitions in a degenerate Fermi gas

    Get PDF
    We measure momentum-resolved Raman spectra of a spin-polarized degenerate Fermi gas of 173^{173}Yb atoms for a wide range of magnetic fields, where the atoms are irradiated by a pair of counterpropagating Raman laser beams as in the conventional spin-orbit coupling scheme. Double resonance of first- and second-order Raman transitions occurs at a certain magnetic field and the spectrum exhibits a doublet splitting for high laser intensities. The measured spectral splitting is quantitatively accounted for by the Autler-Townes effect. We show that our measurement results are consistent with the spinful band structure of a Fermi gas in the spatially oscillating effective magnetic field generated by the Raman laser fields.Comment: 7 pages, 6 figure

    SoC Test Applications Using ACO metaheuristic

    Get PDF

    The Synergic Effects of Flow and Sphingosine 1-Phosphate on Sprouting Angiogenesis Into Three-Dimensional Collagen Matrices

    Get PDF
    The vascular endothelium continually senses and responds to both biochemical and mechanical stimuli to regulate vascular function in health and disease. The purpose of this dissertation was to understand the molecular mechanisms by which endothelial cells (ECs) respond to sphingosine 1-phosphate (S1P) and fluid wall shear stress (WSS) to initiate angiogenesis. To accomplish this, a novel cell culture system was developed to study the combined effects of S1P and WSS on inducing EC invasion into three-dimensional (3-D) collagen matrices. EC invasion required the presence of S1P, with the effects of S1P being enhanced by WSS to an extent comparable with S1P combined with pro-angiogenic growth factor stimulation. The extent of EC invasion depended on the magnitude of WSS in a biphasic manner, with the greatest induction occurring at 5.3 dyn/cm2 WSS. Several proteins have been implicated in EC invasion, including calpain, Akt, vimentin, p21-activated kinase (PAK), and membrane type 1-matrix metalloproteinase (MT1-MMP). Interestingly, activations of calpain and MT1-MMP and phosphorylations of Akt, PAK, and vimentin coincided with, and were required for, S1P- and WSS- induced EC invasion. Further, inhibitors of calpain, MT1-MMP, Akt and PAK all attenuated invasion induced by WSS and S1P. Calpain inhibition reduced Akt phosphorylation, vimentin cleavage, and MT1-MMP membrane translocation, suggesting that calpain regulates MT1-MMP via Akt phosphorylation and vimentin remodeling. Akt inhibition also completely blocked MT1-MMP membrane translocation and decreased phosphorylation of PAK and vimentin. In summary, these results suggest a new molecular pathway by which the combination of S1P and WSS stimulates EC invasion through calpain, Akt, PAK and vimentin to regulate activation and membrane translocation of MT1-MMP in 3-D collagen matrices

    Development of an LCD-Based Visual Field System

    Get PDF
    Background: The present study investigated the diagnostic effectiveness of an LCD-based visual field testing system (LVF) in comparison with the standard automated perimetry Humphrey Field Analyzer II-750i (HFA). Methods: A randomized controlled crossover study was conducted with 202 normal and 128 glaucomatous eyes using both LVF and HFA. The visual field testing systems were compared in terms of mean deviation (MD), pattern standard deviation (PSD), and area under the receiver operating characteristics curve (AUC) of MD and PSD differentiating the normal and glaucomatous eyes. Results: Significant correlations were found between MD measurements from LVF and those from HFA for normal eyes (r = 0.342) and glaucomatous eyes (r = 0.796); slightly higher significant correlations were identified between PSD measurements from LVF and those from HFA for normal eyes (r = 0.363) and glaucomatous eyes (r = 0.828). Furthermore, high AUCs of MD were found as 0.786 for LVF and 0.868 for HFA and AUCs of PSD as 0.913 for LVF and 0.932 for HFA. Conclusion: The comparison results of the present study support the competence of LVF compared with HFA in visual field testing for early detection of glaucoma.11Ysciescopuskc

    Vertically aligned InGaN nanowires with engineered axial In composition for highly efficient visible light emission.

    Get PDF
    We report on the fabrication of novel InGaN nanowires (NWs) with improved crystalline quality and high radiative efficiency for applications as nanoscale visible light emitters. Pristine InGaN NWs grown under a uniform In/Ga molar flow ratio (UIF) exhibited multi-peak white-like emission and a high density of dislocation-like defects. A phase separation and broad emission with non-uniform luminescent clusters were also observed for a single UIF NW investigated by spatially resolved cathodoluminescence. Hence, we proposed a simple approach based on engineering the axial In content by increasing the In/Ga molar flow ratio at the end of NW growth. This new approach yielded samples with a high luminescence intensity, a narrow emission spectrum, and enhanced crystalline quality. Using time-resolved photoluminescence spectroscopy, the UIF NWs exhibited a long radiative recombination time (τr) and low internal quantum efficiency (IQE) due to strong exciton localization and carrier trapping in defect states. In contrast, NWs with engineered In content demonstrated three times higher IQE and a much shorter τr due to mitigated In fluctuation and improved crystal quality

    Creutz ladder in a resonantly shaken 1D optical lattice

    Get PDF
    We report the experimental realization of a Creutz ladder for ultracold fermionic atoms in a resonantly driven 1D optical lattice. The two-leg ladder consists of the two lowest orbital states of the optical lattice and the cross inter-leg links are generated via two-photon resonant coupling between the orbitals by periodic lattice shaking. The characteristic pseudo-spin winding structure in the energy bands of the ladder system is demonstrated using momentum-resolved Ramsey-type interferometric measurements. We discuss a two-tone driving method to extend the inter-leg link control and propose a topological charge pumping scheme for the Creutz ladder system. ©2020 The Author(s). Published by IOP Publishing Ltd on behalf of the Institute of Physics and Deutsche Physikalische Gesellschaf

    Realization of a cross-linked chiral ladder with neutral fermions in an optical lattice by orbital-momentum coupling

    Get PDF
    We report the experimental realization of a cross-linked chiral ladder with ultracold fermionic atoms in an optical lattice. In the ladder, the legs are formed by the orbital states of the optical lattice and the complex inter-leg links are generated by the orbital-changing Raman transitions that are driven by a moving lattice potential superimposed onto the optical lattice. The effective magnetic flux per ladder plaquette is tuned by the spatial periodicity of the moving lattice, and the chiral currents are observed from the asymmetric momentum distributions of the orbitals. The effect of the complex cross links is demonstrated in quench dynamics by measuring the momentum dependence of the inter-orbital coupling strength. We discuss the topological phase transition of the chiral ladder system for the variations of the complex cross links.Comment: 8 pages, 8 figure

    User Recognition Based on Human Body Impulse Response: A Feasibility Study

    Get PDF
    Human recognition technologies for security systems require high reliability and easy accessibility in the advent of the internet of things (IoT). While several biometric approaches have been studied for user recognition, there are demands for more convenient techniques suitable for the IoT devices. Recently, electrical frequency responses of the human body have been unveiled as one of promising biometric signals, but the pilot studies are inconclusive about the characteristics of human body as a transmission medium for electric signals. This paper provides a multi-domain analysis of human body impulse responses (HBIR) measured at the receiver when customized impulse signals are passed through the human body. We analyzed the impulse responses in the time, frequency, and wavelet domains and extracted representative feature vectors using a proposed accumulated difference metric in each domain. The classification performance was tested using the k-nearest neighbors (KNN) algorithm and the support vector machine (SVM) algorithm on 10-day data acquired from five subjects. The average classification accuracies of the simple classifier KNN for the time, frequency, and wavelet features reached 92.99%, 77.01%, and 94.55%, respectively. In addition, the kernel-based SVM slightly improved the accuracies of three features by 0.58%, 2.34%, and 0.42%, respectively. The result shows potential of the proposed approach for user recognition based on HBIR
    corecore